Search results for "Permanent pacemaker"
showing 3 items of 3 documents
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…
Impact of early (<7 days) pacemaker implantation after cardiac surgery on long‐term pacemaker dependency
2021
We aimed to investigate pacemaker dependency after at least 1 year in patients with early (7 days) implantation, compared to those who received a pacemaker ≥7 days after cardiac surgery. Secondary endpoints were length of hospital stay and in-hospital complications.Retrospective analysis of 108 consecutive patients who received a pacemaker after cardiac surgery between 06/2012 and 06/2018. Characteristics and outcomes were compared between patients with early (7 days) and late (≥7 days) implantation. Patients were followed up with evaluation of pacemaker dependency between April and June 2019. We identified predictors of dependency by logistic regression.In total, 63.9% were men, average ag…
Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptation
1999
Abstract Background . Appropriate generator and lead selection as well as techniques of implantation are most important aspects of cardiac pacing in the extremely young patient. Here we report the clinical results using a new technique with automatic output adaptation based on evoked response in combination with steroid-eluting epicardial leads in small children. Methods . One neonate and 2 premature infants underwent permanent pacemaker implantation because of congenital high-degree atrioventricular block or postoperative complete heart block, respectively. Steroid-eluting epicardial leads and a multiprogrammable pacemaker with automatic output adaptation were used. Results . Intermuscular…